Solar export limits: where does your surplus power go?

Read your solar connection offer, distinguish export caps from inverter clipping, and calculate the effect on generation, household use and feed-in credits.

CompareUs Editorial TeamEnergy guides
21 November 2026•9 min read
Photovoltaic panels mounted on a tiled house roof under a clear sky

Your solar quote says the roof will hold 8 kW of panels, but the connection paperwork allows 3 kW of export. Have you just agreed to pay for five kilowatts you cannot use? Those two figures measure different things. The answer depends on what your inverter can produce, how much your home consumes at the same moment and how often the remaining surplus hits the approved limit.

What is a solar export limit?

A solar export limit is the maximum instantaneous power your site is approved to send to the network. Your panels can still supply household demand before any surplus reaches the connection point. The approved limit and whether it can vary depend on your network connection agreement.

Trace one kilowatt-hour from the roof to the bill

Your panels generate direct-current electricity. The inverter supplies alternating-current power that household equipment can use. If the system is generating while you run the dishwasher, some power can go straight to the house. The meter records electricity crossing the grid connection. Export on the retail bill is the electricity that reached the grid after on-site consumption and any battery charging, subject to the way the system and meter are configured.

This explains why an inverter app can report 20 kilowatt-hours of generation for a day while the retailer shows only eight kilowatt-hours of export. The difference can be entirely ordinary. Before looking for a fault, check the monitoring period and how much the household used or stored. A bill covering a month and an app screen showing an exceptionally sunny Tuesday do not describe the same period.

Keep kilowatts and kilowatt-hours in separate columns. Kilowatts describe power at an instant. Kilowatt-hours measure energy over time. Exporting at a steady three kilowatts for two hours sends six kilowatt-hours to the grid. A three-kilowatt limit does not impose a three-kilowatt-hour daily quota. Equally, the existence of that limit does not mean the system will reach it at any particular hour or in any particular season.

Work through a sunny afternoon

The illustrative table shows how the same sunny conditions produce different exports as household use or battery charging changes. The figures describe instantaneous power, not energy over a full day.

Illustrative sunny afternoon, kW
SituationPotential solarHome useBattery chargeExportCurtailed
No battery62031
Home use rises64020
Battery accepts 1 kW62130

Distinguish an export cap from inverter clipping

An inverter has its own output ceiling. When panels could supply more than the inverter can convert, output can flatten at that ceiling. This is commonly called clipping. Export limiting acts on what leaves the site. It can reduce inverter output, but the two ceilings need not be reached at the same time. An array with more panel capacity than inverter capacity is not proof that an export limit is wasting energy.

Illustrative 5 kW inverter with a 3 kW export cap
Home useInverter outputExportBinding limit
1 kW4 kW3 kWExport cap
3 kW5 kW2 kWInverter capacity

Ask for generation, consumption and export on the same time axis. Look at several clear days rather than one fuzzy chart. Cloud passing, shaded panels, high local voltage, equipment temperature and monitoring gaps can all affect the trace. Ausgrid explains that an approved export limit represents a maximum and that actual exports depend on site use, voltage, controls and connectivity. A flat graph is a reason to investigate, not a diagnosis. Ausgrid explanation of export limits

Read the approval alongside the quote

Find the name of the distribution network, the site address, approved inverter configuration and the export conditions. The retailer on your bill may have a completely different name. Ask the installer to identify the document that establishes the network's approval for your property. A salesperson's estimate of what the neighbours were allowed last year is insufficient evidence for your own project.

If the approval uses a per-phase limit, ask how that applies to the installed inverter and supply. Multiplying a quoted single-phase allowance by three simply because a building has three phases can materially overstate revenue. If there is an existing inverter or battery, ask whether the limit applies to the combined site. A second installation at the same address does not automatically receive a separate allowance. CompareUs guide to single-phase and three-phase solar

For a flexible arrangement, ask how the system receives instructions, what happens during a communication outage and where to see the active limit. For a fixed arrangement, ask whether an upgrade would trigger a new assessment. Save the final approved settings with the commissioning documents. Where a system operates under zero export, the controller must manage surplus generation locally. Zero export can still permit on-site solar use, subject to the installation design and connection agreement.

Compare Electricity Plans

General information only, not financial, legal, medical or electrical advice.

CompareUs may receive referral fees. How we get paid.

Calculate the effect on your bill

Begin with the energy that the cap actually prevents you exporting over a representative period. Annual panel generation multiplied by the feed-in tariff will overstate export revenue if the house consumes some of that electricity. Conversely, multiplying the gap between panel and export ratings by every hour of daylight usually overstates curtailment. The output would rarely have been at maximum for all those hours.

Illustrative annual value of 500 kWh
Use of energyAssumed unit rateCalculationValue
Additional export6 c/kWh500 × $0.06$30
Avoided grid imports30 c/kWh500 × $0.30$150

Consider timing and opportunity cost. Running a scheduled appliance during a period when energy would otherwise be curtailed can deliver a different benefit from shifting it into a period when you would otherwise have earned an export credit. Look at the tariff for the time you shift from, too. Moving a load from a cheap overnight period to midday avoids a smaller import charge than moving the same load from an expensive evening period.

A battery adds purchase cost, conversion losses and limits on available capacity. Ask for a comparison showing how much curtailed energy it can realistically capture on the days it is partly empty. Then ask what that stored energy displaces later. If the battery would already fill from solar before lunch, installing more export capacity or more panels need not lead to more evening battery savings. Annual totals without a time profile can conceal that detail.

Ask for a second design before buying extra equipment

If a flexible connection is available, ask for a realistic comparison with the fixed option for your network. Compare equipment cost, operating conditions and expected export over time. A higher permitted maximum can help during periods when the network allows it, the roof is productive and the home has surplus electricity. All three conditions must coincide for the household to receive an additional export credit. SA Power Networks flexible export explanation

Also ask whether a plan offering a higher feed-in rate changes the import price, daily charge or any export payment tiers. Price the whole household bill using the export quantity the site can actually achieve. Two households with identical panels can reach different answers if one charges an EV at home during daylight and the other is empty most of the day.

Check a suspected export fault without touching the settings

Write down the time and date, the inverter's displayed output, any warning message, the battery state and whether large appliances were running. Save a screenshot showing the chart labels. Compare the retailer's export data once the relevant interval is available. If an app lost contact after a router change, tell the installer. Missing monitoring data and a system operating under a fallback limit are separate possibilities to check.

Check the units in any exported spreadsheet before sending it. A half-hour interval showing 1.5 kilowatt-hours of export is consistent with an average of three kilowatts over that interval. Comparing the value 1.5 directly with a three-kilowatt cap would make the system look as though it achieved only half the allowed rate.

Send the installer the approved connection document and those observations. Ask them to confirm whether the configured limit matches approval, whether the monitoring sensors show the correct direction and whether any protective response occurred. Leave configuration changes to authorised professionals. Increasing a setting yourself could put the installation outside its approved conditions without fixing the reason export was low.

Questions to ask your installer

  • What is the approved site export limit and is it fixed or flexible?
  • Do all existing inverters and batteries share that site limit?
  • What readings show generation, household use and export on the same interval?
  • What happens to export control if communications fail?

If the installer confirms electricity is reaching the meter but your bill shows no export credit, ask the retailer about meter configuration, billing dates and the feed-in arrangement on the account. If the installation is operating normally within approved settings, keep the records as a baseline for future changes. On the next bill you will be able to distinguish a lower tariff from lower export volume, and both from a real change in the performance of the roof.

A network export limit is a maximum, not a production forecast.

For a bill comparison, use your actual usage and export data.

Estimate import costs with the electricity cost calculator.

The rooftop system design also depends on supply phases.

Where should you go next?

FAQs

Does a five-kilowatt export limit mean I can only have five kilowatts of panels?

Panel rating, inverter capacity and approved export are different figures. Ask the installer which combination the distributor has approved for your property.

Can zero-export solar power my appliances?

A suitable system can supply on-site loads while controls prevent surplus export. Check the approved arrangement and the amount of demand during solar hours.

Does my retailer set the export cap?

The network connection agreement governs permitted export. The retailer sets the feed-in payment terms on your account.

Can I tell how much solar was curtailed from the electricity bill?

The bill usually shows metered exports. Estimating potential generation that was curtailed requires additional production, household load and system information.

Does adding a battery lift the export limit?

The connection conditions still apply. Storage can absorb surplus when it has capacity and is configured to charge, subject to the system design.